Skip to content

Cash on Delivery all over Pakistan · Free delivery in Islamabad & Rawalpindi above Rs 5,000

PakCircuit
UNI-T UT523A Earth Resistance & Soil Resistivity Tester - 0~210 kΩ, Soil Resistivity (Wenner), Earth Voltage AC 0~750 V, 4-Pole, Auto-Range

UNI-T UT523A Earth Resistance & Soil Resistivity Tester - 0~210 kΩ, Soil Resistivity (Wenner), Earth Voltage AC 0~750 V, 4-Pole, Auto-Range

The UNI-T UT523A is a professional earth resistance and soil resistivity tester for grounding-system commissioning and maintenance - measuring earth (ground)…

Rs 106,250
In stock Price updated 15 Nov 2026
Total: Rs 106,250
  • Delivery in 2 to 4 working daysFree in Islamabad & Rawalpindi above Rs 5,000
  • Cash on deliveryPay when your parcel arrives
  • 7-day checking warrantyDead-on-arrival items replaced
  • Packed with careAnti-static & padded packaging

Highlights

  • 🌍 Earth resistance 0.00 Ω ~ 210 kΩ at ±(2%+5) , auto-range
  • 🪨 Soil resistivity (ρ) by 4-pole Wenner method , up to 9000 kΩ·m
  • ⚡ Earth voltage AC 0 ~ 750 V measurement
  • 📡 AFC test frequencies (128/111/105/94 Hz) reject stray interference
  • 🔧 Rated-current pole-changing method, max 20 mA test current
  • 🛡️ Short-circuit current ≤30 mA, open-circuit ≤40 V; auto power-off
  • UT523A earth / soil resistivity tester
  • Test lead set

Specifications

Earth resistance range
0.00 Ω ~ 210 kΩ (5 ranges)
Earth resistance accuracy
±(2% + 5)
Soil resistivity range
0 Ω·m ~ 9000 kΩ·m (ρ = 2πaR, Wenner method)
Earth voltage
AC 0.00 ~ 750 V, ±(2% + 5)
Test frequencies
128 / 111 / 105 / 94 Hz (AFC)
Measuring current (earth R)
Rated-current pole-changing, max 20 mA
Short-circuit test current
AC 30 mA max
Open-circuit test voltage
AC 40 V max
Auto range
Yes

About this product

The UNI-T UT523A is a professional earth resistance and soil resistivity tester for grounding-system commissioning and maintenance - measuring earth (ground) resistance up to 210 kΩ , soil resistivity by the 4-pole Wenner method, and earth voltage up to AC 750 V .

It uses a rated-current pole-changing method (max 20 mA) with automatic AFC test frequencies (128/111/105/94 Hz) to reject interference, auto-ranges across all scales, and holds ±(2%+5) accuracy - ideal for substations, lightning-protection systems, towers and electrical installations.

Key Features

Technical Specifications

Earth resistance range

0.00 Ω ~ 210 kΩ (5 ranges)

Earth resistance accuracy

±(2% + 5)

Soil resistivity range

0 Ω·m ~ 9000 kΩ·m (ρ = 2πaR, Wenner method)

Earth voltage

AC 0.00 ~ 750 V, ±(2% + 5)

Test frequencies

128 / 111 / 105 / 94 Hz (AFC)