5V 2 CH SSR High Level Solid State Relay Module AC 240V/2A
5V 2 CH SSR high Level Solid State Relay Module AC 240V/2A has a longer life, with a much higher turn on/off speed and no noise.
- Delivery in 2 to 4 working daysFree in Islamabad & Rawalpindi above Rs 5,000
- Cash on deliveryPay when your parcel arrives
- 7-day checking warrantyDead-on-arrival items replaced
- Packed with careAnti-static & padded packaging
Highlights
- Triggered at High level (or Active high )
- Separate LEDs showing status of each Solid-State Relay
- High Signal (Solid-State Relay OFF / OPEN), 3.3V - 5.0V or leave it floating
Specifications
- Rated output load
- 100V ~ 240V AC (50Hz/ 60Hz) 2A per channel
- Rated input power
- 5V, 160mA (all channels ON)
- Input control signal
- • Low Signal (Solid-State Relay ON / CLOSE), 0V- 2V or GND
- Dimension
- 55mm x 34mm x 25mm
- DC+
- Connect the positive pole of the power supply (power supply according to the relay voltage)
- DC
- Connect the negative pole of the power supply
- CH1
- 1 Relay module signal trigger end (low level trigger is valid)
- CH2
- 2 way relay module signal trigger end (low level trigger is valid)
About this product
5V 2 CH SSR high Level Solid State Relay Module AC 240V/2A has a longer life, with a much higher turn on/off speed and no noise. Buy online in Pakistan
A two-channel relay module featuring 2x G3MB-202P solid state relays. A Solid State Relay is similar to a mechanic relay where it can be controlled through a digital signal. Solid State Relay generates no noise and has a much longer lifespan in compared to the traditional mechanic relay.
Features
•Input control signal:
•Low Signal (Solid-State Relay ON / CLOSE), 0V- 2V or GND
•High-level triggering :There is a forward voltage between the signal trigger terminal (IN) and the negative pole of the power supply. Usually , a triggering method is used to connect the positive pole of the power supply to the trigger terminal. When the trigger terminal has a positive voltage or triggers. At the voltage, the relay pulls in.
•Low-level triggering : The voltage between the signal trigger terminal and the negative pole of the power supply is OV, or the voltage at the trigger terminal is lower than the voltage of the positive pole of the power supply. When the voltage is low enough to trigger, the relay is pulled in, usually A triggering method in which the negative pole of the power supply is connected to the trigger terminal , so that the relay is attracted.